This presentation is all about membrane rejection, how to calculate it, where to sample for it, and what the numbers are telling us. Knowing how to collect and analyze this information on a RO membrane system will allow an operator to setup a conductivity profile and then a rejection profile for all parts of the RO process. Using these skills will allow for a much earlier detection of potential membrane issues which will ultimately help extend membrane life. Case study examples will be used to support the methodology.

Details
First NameTom
Last NameImbornone
KeywordsRO Membrane Systems, Conductivity Profiling, Rejection Loss Causes
Year22