Paper presents the deisng considerations of the Jurong membrane bioreactor treatment facility in Singapore. The plant was designed retrofitting existing aeration basins with a membrane bioreactor to produce effluent which is suitable for reuse in industrial applications. Report outlines steps taken that are expected to reduce overall energy consumption of the plant by 15% compared to most conventional membrane bioreactors.

Details
First NameBen / Eric Liu / Shinya / Yasuo
Last NameFreeman, E.I.T. / Hongyu / Sunano / Oda
KeywordsRetrofitting, reuse, membrane bioreactor
Year12