The City of Fargo, ND, owns and operates a 15 MGD membrane WTP that treats surface water that has high fouling potential: 8-16 mg/L organics, TDS up to 1,000 mg/L, and wide temperature swing 33-85 ∞F. The plant faces various challenges through seasons: pretreatment upsets (poor settling) and high operating pressures in winter and spring, severe organic/bio fouling, and rapid differential pressure (DP) rising in summer. This presentation will cover the pilot study, a few important investigations the plant performed to improve the operations to consistently produce high quality drinking and shares the successful experiences to reduce the fouling potential, a new UF membrane fiber repair approach, bio-fouling mitigating options, reversed permeate flush and CIP.
Fargo 15 MGD Integrated Membrane WTP: Pilot Study, Design, Operation and Optimization
| Details | |
|---|---|
| First Name | Qigang |
| Last Name | Chang |
| Keywords | Membrane, Pilot Study, Operation Optimization |
| Year | 22 |
| File | 3-6_Chang_Qigang_Presentation.pdf |