This paper describes a model that can be used to assess RO membrane performance using local hydraulic resistances and local fouling rates. The model links measured plant parameters with the internal characteristics of RO membranes and was calibrated using RO projection programs, operation data or literature data.

Details
First NameSeung-Min / Jihee / Sangho / June-Seok / Wontae
Last NamePark / Han / Lee / Choi / Lee
Keywordsoperations,/maintenance optimization, modeling
Year12