This paper presents the results from a twelve-month pilot study using ceramic membranes on Lake Michigan water in a sustainable manner with a flux of 103 gfd (175 lmh), with chlorinated and acidic chemically enhanced backwashes, and with pre-treatment with polyaluminum chloride coagulation. They estimate that the cleaning interval could be up to 10 months. It was necessary to apply pre-coagulation upstream of the ceramic membranes for sustainable operation.
Ceramic Membrane Pilot Testing on Lake Michigan
| Details | |
|---|---|
| First Name | Holly / Rob / Paul / Gilbert / Jumeng |
| Last Name | Shorney-Darby, PhD, PE / Michaelson / Aumann / Galjaard / Zheng, PhD |
| Keywords | ceramic, ultrafiltration, Lake Michigan, cleaning, pilot |
| Year | 16 |
| File | W-10-02_ShorneyDarbyHolly.pdf |