A new method for direct measurement of the abrasion propensity of UF membranes used in water treatment plants was developed. Standard conditions were determined to obtain a rapid response.

Details
First NameAngelique / Anne / Philippe / Yvan
Last NameFabre / Brehant / Moulin / Wyart
KeywordsPlant Operation, Maintenance, Management
Year19
FileT-2-3_Fabre_Angelique_Brehant_Anne_Moulin_Philippe_Wyart_Yvan.pdf